Service OAM 9145E NID Software User’s Manual
Maintenance Entity Groups
221
11.6.7 Delete a Maintenance Entity Group
When you delete a Maintenance Entity Group, all MEPs/MIPs associated with it are also deleted
from the AIS client lists.
1. On the Maintenance Entity Group List screen (Figure 11-15), type D and press Enter. The
current Maintenance Entity Group is highlighted.
2. Press the Space bar to scroll through the list and highlight the entry you want to delete.
3. Press Enter to delete the highlighted Maintenance Entity Group. You are prompted to
confirm the deletion.
11.5.4 Modify a Maintenance Entity Group
1. On the Maintenance Entity Group List screen (Figure 11-15), type E and press Enter. The
current MEG is highlighted.
2. Press the Space bar to scroll through the Maintenance Entity Groups and highlight a
MEG to modify.
3. When the item you want to modify is highlighted, press Enter. The Maintenance Entity
Group Attributes screen (Figure 11-17) opens.
4. To change the CCM interval, type 1 and press Enter. The CCM interval is the interval at
which CCMs are sent by a MEP. Select 1 sec, 10 sec, or 100 ms, and press Enter.
NOTE: No more than two MEPs at 100msec are supported. Typically, these MEPs are used at
MEG level 0 to monitor the physical line.
5. To add a VLAN to the VLAN list of this MEG, type 2 and press Enter. You are prompted to
type a new VLAN ID. Type the VLAN ID and press Enter. The VLAN appears in the list.
Up to four VLANs can be added for each MA.
NOTE: For S-Tag MEGs, the VLAN value is taken automatically from the SOAM All-to-One
Bundling Tunnel configuration and cannot be changed.
6. To remove a VLAN from the list, type 3 and press Enter. You are prompted to type the
number of the VLAN to remove. Type the VLAN number and press Enter.
Some restrictions apply to modifying and deleting VLANs:
• The first VLAN is the primary VLAN and cannot be modified.
• To delete the primary VLAN, you must delete all VLANs in the list and create a
new list.
If a VLAN list is shared by two or more MAs/MEGs, it cannot be modified from this
user interface.
7. You can view or modify the peer MEPs list. Type 4 and press Enter. The Maintenance
Entity Group Peer MEPs screen opens.
To add a peer MEP, type 1 and press Enter. You are prompted for the MEP ID
number. Type the number and press Enter.