Canoga-perkins 9145E NID Software Version 4.10 Manuel d'utilisateur Page 133

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 296
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 132
Diagnostics 9145E NID Software User’s Manual
Service Activation Testing
121
8. To view a CIR test report, type 4 and press Enter. The CIR Test Report screen (Figure 4-
77) opens.
Figure 4-77 CIR Test Report screen
9. To view details, type D and press Enter. The Detailed CIR Test Report (Figure 4-78)
opens.
Canoga Perkins Corp. Ethernet Network Interface Device 29-JAN-2009
9145E-761-0-0 V41.66 23:47:13
------------------------------- CIR TEST REPORT --------------------------------
Test Id : 1 Name : T-1
Ingress CE-VLAN: 1000 PCP: 3 Egress CE-VLAN: 1000 PCP: 3
SA Profile : SA-1
CIR: 200 Mbps CBS: 80 Kbytes EIR: 600Mbps EBS: 16Kbytes
Status : pass/fail
Total elapsed time (s) : 1000 Step duration (s): 10 Executed steps: 2
Direction Actual Tx Rx FLR Avg Rx IR Avg DM Avg DMV Result
Rate (Mbps) Frames Frames (%) (Mbps) (usec) (usec)
NE->FE 1000 209 205 55.55 999 197 209 Failed
NE->FE 750 209 205 55.55 702 12 12 Pass
FE->NE 1000 207 201 55.55 765 200 2 Failed
FE->NE 750 209 205 55.55 702 12 12 Pass
Select [(F)irst, (P)rev, (N)ext, (L)ast, (D) details]:
------------------------------------Messages----------------------------------
Vue de la page 132
1 2 ... 128 129 130 131 132 133 134 135 136 137 138 ... 295 296

Commentaires sur ces manuels

Pas de commentaire