CanogaOS Configuration Guide
39-7
address. If two different host entries on the same RADIUS server are configured for the
same service—for example, authentication—the second host entry configured acts as
the fail-over backup to the first one. The RADIUS host entries are tried in the order that
they were configured. In this release, up to 3 RADIUS server can be configured.
DUT# configure terminal Enter the Configure mode.
DUT(config)#radius-server host
202.38.100.7 key test retransmit 3
timeout 5 auth-port 1812
Configure the RADIUS server parameters on the switch.
The key is a text string that must match the encryption key used
on the RADIUS server.
If you want to use multiple RADIUS servers, re-enter this command.
DUT(config)# radius-server
deadtime 5
Specify the server active period, the default is 5 minutes.